Skip to main content

Join us at Gartner SEC London and discover how LevelBlue can help you secure what’s next. Learn More

Loading...
Loading...

INFO: R3000's are not able to synchronize with each other

Expand / Collapse


This article applies to:

  • R3000

Question:

R3000's are not able to synchronize with each other

Reply

 Please check the following settings in your R3000 appliance:

In System -> Synchronization, you need to configure one server as the “source” box, and the other sever as the “target.” 
For synchronization to work, all of the servers must be at the same software version.  The current version number appears at the bottom of the “Home” window.

Make sure that the servers can communicate with each other on following TCP ports: 

26260
26262
26265
26266
26267
26268 


This article was previously published as:
8e6 KB 276587

To contact LevelBlue about this article or to request support: